Gross internal area (GIA) is the floor area of a building measured to the internal face of the perimeter walls at each floor level, with internal walls, stairwells and lift wells left in. To measure it, take each floor as one closed shape inside the external walls, apply the Code's inclusions and exclusions to stairs, voids and low-headroom space, add the floors together, and write down the basis you used. The rules come from the RICS Code of Measuring Practice, and most disputed figures trace back to a basis that was never stated.
This guide is for QSs at SME firms, small builders and architects who need a GIA they can defend, whether it feeds a cost plan, a CIL (Community Infrastructure Levy) form or a service-charge schedule.
TL;DR
- GIA is measured to the internal face of the perimeter walls on every floor. Perimeter wall thickness is out; internal walls, partitions, columns and chimney breasts are in.
- The definition is in the RICS Code of Measuring Practice, 6th edition. RICS says members should keep using it, and/or IPMS: All Buildings, until the 7th edition is published.
- Low headroom, car ports, attics and voids are where figures diverge between the RICS Code, VOA rating definitions and local CIL guidance.
- Check the total against the sum of room areas: the gap should be roughly the internal wall area, and if it isn't, find out why.
- Always state the standard, the basis and a separate list of excluded areas with their sizes.
Table of Contents
- What GIA means and where it is used
- Which standard to use
- What is included in GIA
- Where the standards disagree
- Floors, stairs, voids and awkward outlines
- How to measure GIA from drawings, step by step
- A worked example
- Common errors and how to catch them
- Where drawing-based software fits
- FAQ
- Sources
What GIA means and where it is used
The RICS Code defines GIA as the area of a building measured to the internal face of the perimeter walls at each floor level. The Code lists its uses as building cost estimation, marketing and valuation of specified building types, rating in England and Wales for specified classes, service-charge apportionment, and valuation and marketing of residential dwellings, particularly new developments, using a modified version (RICS Code, 6th edition).
For a QS the most common use is cost planning. RICS NRM1 describes a floor-area method in which total gross internal floor area (GIFA) is multiplied by a suitable cost per m² of GIFA to estimate building cost (NRM1, 2nd edition). The area you pick sets the rate you can fairly apply, so an inconsistent GIA undermines the whole estimate.
The second common use is planning. Councils charging CIL ask for GIA, and most point applicants to the RICS Code. Bassetlaw District Council's guidance note, for example, states that GIA is measured to the internal face of the perimeter walls at each floor level under the Code (Bassetlaw guidance note).
GIA, GEA, NIA and GIFA
These terms get mixed up on live jobs:
| Measure | Measured to | Typical use |
|---|---|---|
| GIA | Internal face of perimeter walls | Cost estimating, rating of some building types, service charges |
| GEA (gross external area) | External face of the walls | Planning site coverage and plot ratio, residential insurance |
| NIA (net internal area) | Usable space, excluding items such as circulation cores and plant | Marketing offices and shops |
| GIFA | Gross internal floor area, the term NRM1 uses for cost-per-m² estimating | Cost planning |
On marketing, the Code advises surveyors to rely principally on NIA for commercial property and to treat GEA and GIA as suited to specialist applications. Anyone marketing on a GIA basis is told to take particular care, because items such as voids over stairwells could mislead if not clearly stated (RICS Code as republished by Guildford Borough Council).
Which standard to use
RICS states that, until the final 7th edition of the Code is published, members and regulated firms should continue to use the 6th edition and/or IPMS: All Buildings. They should adopt the basis that fits the instruction and document it (RICS Code of Measuring Practice page).
IPMS (International Property Measurement Standards) is the international alternative. Its All Buildings standard asks for measurements taken horizontally (height excepted), supported by computer-generated drawings where available, with annotated dimensions preferred over scaling. It also asks for independent verification on site where possible and reporting level by level, stating the standard, method, tools, units, date and verification (IPMS: All Buildings). The earlier RICS Property Measurement statement equated IPMS 2 – Office closely to the former GIA, so you may see both figures on larger commercial instructions (RICS Property Measurement, 2nd edition).
For a CIL form, use the definition the local authority names, which is usually the RICS Code. For rating work in England and Wales, the Valuation Office Agency (VOA) publishes its own definitions, which differ in places.
What is included in GIA
The Code's inclusions are specific. Under the 6th edition, GIA includes:
- internal walls and partitions (clause 2.1)
- columns, piers, chimney breasts, stairwells, lift wells and vertical ducts (2.2)
- atria, at base level only (2.3)
- mezzanine floors with permanent access (2.8)
- lift, plant, fuel and tank rooms in permanent covered structures (2.9)
- service accommodation such as toilets and showers (2.10)
- voids over stairwells and lift shafts on upper floors (2.12)
- loading bays (2.13)
- areas with headroom under 1.5 m (2.14)
- garages (2.16) and conservatories (2.17)
The Code excludes perimeter wall thicknesses and external projections, external open-sided balconies, covered ways and fire escapes, canopies, voids over or under structural, raked or stepped floors, and greenhouses, garden stores and fuel stores in residential property (RICS Code, 6th edition).
One note matters on refurbishment work. Under note GIA 4, the "internal face" means the brickwork or blockwork, or the plaster coat applied to it. It is not the surface of internal linings installed by an occupier. Measure to the structure, not to a dry-lined or boxed-in finish that a tenant added later.

Where the standards disagree
The same space can be treated three ways depending on who is asking.
Low headroom. The RICS Code includes areas with headroom under 1.5 m in GIA. The VOA's rating definitions exclude any area with a ceiling height under 1.5 m, except under stairways, and say excluded areas should be calculated and shown separately (VOA definitions for rating purposes, 2012). If you are measuring a loft or eaves space, decide which question you are answering before you pick a rule. Our loft conversion takeoff guide covers how those areas feed a measured bill.
Attics and car ports. Local CIL guidance adds its own clarifications. Rutland County Council's August 2025 guidance adopts the Code's GIA definition. It counts an attic if reached by a fixed permanent stairway or ladder but not by a pull-down ladder. Attic space under 1.5 m is included if easily accessible, and excluded if it has no access and no flooring. A car port walled on three sides and roofed counts as a garage and is included; with two walls or fewer it is a canopy and is excluded (Rutland CIL floorspace guidance). Covered external swimming pools are included, and uncovered pools fall outside CIL scope, according to the same guidance.
The lesson is not that one rule is right. Read the instruction, find the authority's guidance, and record which rule you applied.

Floors, stairs, voids and awkward outlines
The Code gives clear treatment for the shapes that cause most trouble:
- Floor levels. GIA is measured at each floor level. Structural, raked or stepped floors are treated as level floors, measured horizontally. Note steps or changes in floor level.
- Stairwells and lift shafts. Voids over them are included on upper floors, so the stair is counted on every storey it passes through.
- Atria. Measured at base level only, with voids over atria excluded at upper levels. An atrium-like entrance feature that also holds a staircase is still an atrium.
- Separate buildings. Identify them first. GIA excludes perimeter wall thickness but includes internal wall thickness, so deciding where one building ends and the next begins changes the answer.
On that last point, the VOA treats elements not united in a common form of construction as separate buildings. Contiguous elements of similar construction count as one building where more than 50% of the party wall has been removed (VOA definitions).
For a situation none of these cover, IPMS says to extrapolate the principles using a logical, consistent approach supported by an explanation (IPMS: All Buildings). In practice that means writing your reasoning into the schedule.
How to measure GIA from drawings, step by step
The method is the same whether you work from paper, PDFs or a CAD plan.
1. Confirm the drawings and scale
Use the latest issued plan for each floor and check the stated scale against a known dimension. The IPMS preference for annotated dimensions over scaling is sound: where a figure is written on the drawing, use it. Our guide to the role of drawings in quantity measurement sets out how to read the drawing set before you start.
2. Fix the basis
Decide whether you are working to the RICS Code, to IPMS, or to a council's CIL guidance, and write that at the top of your sheet. Everything after it depends on this.
3. Trace each floor as one closed shape
Follow the internal face of the perimeter walls and close the outline. Do not deduct internal walls, partitions, columns or chimney breasts: they stay in. Do not add the thickness of the external wall.
4. Apply the rules to stairs, voids and low headroom
Work through the inclusions and exclusions above floor by floor. Count the stairwell on each level, include voids over stairs and lift shafts on upper floors, and treat headroom under 1.5 m according to your chosen basis.
5. List exclusions separately
Write excluded areas on their own lines with their sizes: balconies, canopies, external stores. The VOA asks for the same practice for rating, and it lets a reviewer rebuild the figure on another basis without going back to the drawings.
6. Add the floors and sense-check
Sum the floors, then compare with the total of room areas. Room areas from CAD or BIM models are usually taken inside each room boundary, so they fall short of GIA by roughly the internal wall area on plan. If the gap is much bigger or smaller than the wall area, look for a missed stair, a void counted twice or a room outside the outline.
7. Report the basis
State the standard, method, tools, units and date, as IPMS requires, and say whether the figures were checked on site.
A worked example
Take an illustrative two-storey detached house, measured to the RICS Code. The ground-floor plan shows an external footprint of 8.00 m by 6.00 m with 0.30 m thick external walls.
- Internal dimensions: (8.00 − 0.60) × (6.00 − 0.60) = 7.40 m × 5.40 m = 39.96 m²
- Internal walls and partitions: not deducted
- Stairwell: included on the ground floor and again on the first floor, with the void over it counted on the upper floor
- First floor: same footprint, 39.96 m²
- GIA: 39.96 + 39.96 = 79.92 m²
The GEA for the same house would be 8.00 × 6.00 × 2 = 96.00 m². The 16.08 m² difference is the external wall thickness on both floors. If the schedule just said "80 m²" without the basis, a reader could not tell which of those two numbers it came from. That is exactly how area disputes start.
Now suppose the same house has a garage under a lean-to roof, walled on three sides. Under the Rutland guidance it counts as a garage and goes in; with two walls it would be a canopy and stay out. Either way, put the decision on the sheet. A house extension raises the same questions about boundaries and wall thickness, which our house extension takeoff checks work through.
Common errors and how to catch them
Most wrong GIA figures come from a short list of causes:
- Measuring to the external face, which is GEA, not GIA.
- Deducting internal walls, which should stay in.
- Mixing the Code and IPMS in one schedule without saying so.
- Measuring to an occupier's lining rather than the structural or plastered face.
- Applying one body's headroom rule where the instruction calls for another.
- Leaving the measurement basis off the schedule altogether.
A short review routine catches most of them: a second person re-traces one floor, the total is compared with room areas, and every exclusion has a line. Our construction measurement quality control guide describes review habits that suit a small team.
Where drawing-based software fits
GIA is the first quantity on most jobs, and the rest of the take-off builds on it: floor finishes, ceilings, plastering and cost per m² all refer back to it. Tracing it by hand from a PDF is slow and easy to get wrong when sheets are revised.
QuantiFlow is a UK tool, still in development, that reads construction drawings and produces a draft Bill of Quantities for a quantity surveyor to review and sign off. The judgement calls in this guide, such as which basis applies and how a void or car port is treated, stay with the surveyor. You can see the plans at quantiflow.co.uk.
FAQ
Is gross internal area measured to the inside or outside of the walls?
The inside. GIA is taken to the internal face of the perimeter walls at each floor level, which is the brick or blockwork or the plaster coat on it. Measuring to the outside face gives gross external area (GEA), a different measure used for things such as planning site coverage.
Are internal walls included in GIA?
Yes. The RICS Code includes internal walls and partitions, columns, piers and chimney breasts in GIA, so you do not deduct them. Only the thickness of the perimeter walls is left out.
Does GIA include space with headroom below 1.5 m?
Under the RICS Code, yes. The VOA's rating definitions exclude it, except under stairways, and local CIL guidance can add conditions about access and flooring. Use the rule that matches the purpose of your instruction and state it.
Which standard should I cite for a GIA figure now?
RICS says members should use the 6th edition Code and/or IPMS: All Buildings until the 7th edition is published, adopt the basis suited to the instruction and document it. For a CIL form, follow the standard the council names.
What should a GIA schedule record?
The standard and edition, the measurement method and tools, the units and date, the area of each floor, and a separate list of excluded areas with their sizes. IPMS asks for much of this, and it lets a reviewer check or restate the figure without re-measuring.
Sources
- RICS Code of Measuring Practice, 6th edition (May 2015)
- RICS Code of Measuring Practice page
- RICS Code as republished by Guildford Borough Council
- RICS NRM1, 2nd edition
- RICS Property Measurement, 2nd edition (January 2018)
- IPMS: All Buildings
- VOA definitions for rating purposes (2 October 2012)
- Rutland County Council CIL floorspace guidance (August 2025)
- Bassetlaw District Council GIA guidance note
Recommended
- Metric vs imperial in UK construction: what QSs need to know
- Construction measurement quality control: the UK SME guide
- Fit-Out Quantity Takeoff: A Step-by-Step Guide for UK QSs
- UK QSs: Stop NRM2 Measurement Mistakes With Practical QA Steps
This article is for general information only and is not professional, legal or commercial advice. Quantity surveying decisions should be taken by a qualified professional with reference to the specific project, drawings and contract in question. Content is produced with AI assistance and reviewed before publication. QuantiFlow Ltd accepts no liability for reliance on it.